OPERATING INSTRUCTIONS
Switching the air compressor OFF
To switch the air compressor off,
1. Close the outlet tap and press down the on/off switch (red button)
located on top of the air compressor.
2. Switch off the mains supply and remove the plug.
• You should never leave the compressor air reservoir unattended while
under pressure, as this may result in an accident.
• Always release the pressure from the reservoir when not in use or prior
to storage, as described in 'Draining the reservoir' on page 18.
Removing a tool from the air hose
WARNING!
Always set the pressure regulator to zero before attempting to remove or
replace a tool.
1 Press down the on/off switch (red button) located on top of the air
compressor.
2 Close the air outlet tap and trigger the equipment (spraygun, air tool etc),
to release air from the air hose BEFORE disconnecting the hose from the
machine.
Reset button
This compressor is equipped with a thermal
overload device, which operates as a
safety device to protect the motor.
When the motor overheats for any reason,
the overload cutout automatically cuts
the power thereby preventing damage to
the motor.
Wait around 5 minutes for the motor to
cool and press the reset button.
If you restart the compressor and the
overload cutout activates again, switch off the compressor, remove the plug
from the mains and have your compressor checked by a qualified service
agent.
Figure 9