TROUBLESHOOTING
70
H6, HH
Description
H6 indicates a DC fan error.
HH indicates that H6 protection has occurred 10 times in 2 hours. When HH error occurs, a manual system
restart is required before the system can resume operation. The cause of HH error should be addressed
promptly in order to avoid system damage.
The unit shuts down.
The error code is displayed on the main PCB and user interface.
Possible causes
Fan communication or controller wiring is not connected properly.
High wind speed.
Fan motor blocked or failed.
Abnormal power supply.
Inverter module damaged.
Main PCB is damaged.