EasyManuals Logo

Cloudray DM422S User Manual

Cloudray DM422S
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
DM422S USER MANUAL
www.cloudratmotor.com
8
minded that the current can not be 1.5times over than the rated current.
4.2 The setting of pulse per revolution
Stepping
count/revolution
SW5
SW6
SW7
SW8
Remarks
200
on
on
on
on
Other Subdivision can be custom-made
400
off
on
on
on
800
on
off
on
on
1600
off
off
on
on
3200
on
on
off
on
6400
off
on
off
on
12800
on
off
off
on
25600
off
off
off
on
1000
on
on
on
off
2000
off
on
on
off
4000
on
off
on
off
5000
off
off
on
off
8000
on
on
off
off
10000
off
on
off
off
20000
on
off
off
Off
25000
off
off
off
off
DIP SW5, SW6, SW7, SW8 are used to set the number of pulses required per revolution of the motor.
Motor speed = command pulse frequency / per revolution pulse
Motor stroke = number of command pulses / pulse per revolution
4.3 Half / full flow selection
DIP SW4 is used to set the quiescent current value when the motor stops.
Off means that when the drive power-on pulse stops, the driver switches the current output to the motor to half
of the rotation (half-flow);
On indicates that the drive maintains the same current output as the rotation to the motor (full flow) when the
drive power-on pulse is stopped. In general use, SW4 should be set to off, so that the heat generated by the
motor and the driver is reduced, and the reliability is improved.
5. Drive working status LED indication
LED status
Drive status
Green indicator is on for long time
Drive not enabled

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cloudray DM422S and is the answer not in the manual?

Cloudray DM422S Specifications

General IconGeneral
BrandCloudray
ModelDM422S
CategoryDC Drives
LanguageEnglish