22
APPENDIX D
In-PlaceQuartzTubeCleaning
The DEL AOP 50 Quartz Tubes may be cleaned without removing them
from the vessel. Ensure that the DEL AOP 50 is isolated from the rest of
the pool system with valves at the inlet and outlet (as shown in Figure 3).
Use the 1/8” FNPT ports at the top and bottom of the vessel to connect
the cleaning system. Flow the cleaning solution from bottom to top. When
cleaning is complete, drain the DEL AOP 50 completely from the bottom
port and run the pool system immediately for an extended period to fully
rinse the internal components. Special considerations may apply depending
on the cleaning system. Contact Customer Service if there is any question
about compatibility with the DEL AOP 50 components.
1/8 FNPT Port
(behind Tee)
1/8 FNPT Port