C32 (Rev. 5) User Manual
___________________________________________________________________________
User’s Manual Page 7
Onboard DIPSWITCH allows activating or deactivating the SCHP detection function.
SWITCH 2 ON: Activate the SCHP detection function.
SWITCH 2 OFF: Deactivate the SCHP detection function.
Note:When the Safety Charge Pump function is activated, 5V are present in the E-Stop
terminal and a valid SCHP signal is present, Port 2 Pin 17 will go high. This high signal
can be used to enable other external devices, such as enabling other Breakout Boards,
or relays that would enable servos, VFDs, contactors, etc….Variable Speed Control
(pin 14 “Port 1” ) and VFD connection.
For Configuring the Charge Pump in Mach X:
Use the dialog Config / Ports and pins / Output Signals. Enable the Charge Pump
output and configure it as is shown in the Fig. 12 Next, press the apply button.