EasyManua.ls Logo

COBHAM AVIATOR UAV 200 - Environmental Compliance (DO-160 G); DO-160 G Test Categories

COBHAM AVIATOR UAV 200
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document: 677-A0219_IM issue 1.4
COBHAM PUBLIC
Page 25 of 61
7.2 ENVIRONMENTAL SPECIFICATIONS
7.2.1 DO-160 Tests
The terminal is designed and tested to meet the RTCA DO-160G [4] sections and categories as listed below
in Table 7-2.
Table 7-2: DO-160G Environmental Requirements
Conditions
Section
Description of Tests Conducted
Temperature and Altitude
Operating Low Temperature
Operating High Temperature
Short Time Operating Low
Short Time Operating High
Ground survival low:
Ground survival high:
In-Flight Loss of Cooling
Altitude:
Decompression:
Overpressure:
4
4.5.2
4.5.4
4.5.1
4.5.3
4.5.1
4.5.3
4.5.5
4.5.1
4.5.1
4.5.1
Category Z (Customised)
-40 °C
+55 °C
-40 °C
+55 °C
-55 °C
+85 °C
Category X (No test performed)
6000 m (20,000 ft.)
Category X (No test performed)
Category X (No test performed)
Temperature Variation
5
Category B (5 °C /min)
Humidity
6
Category A (Standard Humidity Environment)
Shock & Crash Safety
7
Category D (Low frequency operational shock)
Vibration
8
Category S(LM):
Aircraft zone 1 and 2 for fixed wing reciprocating and
turboprop engines, multi-engine over 5,700 kg (12,500 lbs),
multi-engine less than 5,700 kg (12,500 lbs), and single-
engine less than 5,700 kg (12,500 lbs) using vibration test
curves L and M.
Explosive Atmosphere
9
Category X (No test performed)
Waterproofness
10
Category Y (Condensing Test)
Fluids Susceptibility
11
Category F:
Aviation Piston Engine Fuel
Automotive Fuel
Lubricating Oils:
o Mineral, Ester-based and 15W40 engine oil.
Sand & Dust
12
Category S
Fungus Resistance
13
Category X (No test performed)
Salt Fog
14
Category X (No test performed)
Magnetic Effect
15
Category Z (Less than 1 degree deflection at 0.3 m).
Power Input
16
Category Z
Suitable for 14 VDC and 28 VDC systems
Ripple and inrush current measure only
Normal/abnormal operation 10.25 VDC to 32.5 VDC
Emergency operation down to 8 VDC
Surge 50 VDC for 50 ms and (Reset allowed, auto recover)
6 VDC for 30 ms (Reset allowed, auto recover)
Abnormal Surge (No test performed)
Power Interruption (No test performed)
Voltage Spike
17
Category X (No test performed)