Chapter 4: Using the Terminal Control Unit
Configuration 37
44444
Using the Terminal
Configuring the IP address of the Terminal Control
Unit
1. Connect a computer to the RS-232 interface or the LAN interface and
start a terminal program as described in the previous section Using
commands.
2. Log in as a system administrator:
tt6194:/$ su sysadm
Enter password:
To see current system configuration
To see the current configuration type:
tt6194:/$ sysconf
The Terminal Control Unit returns (example):
tt6194:/$ sysconf
Model type : 0
Serial number : 0340530091
PCB ID : 0340530091
BOM : D.00
Unit BOM :
PCB revision :
PCB variant : 0
Location :
MAC : 00:11:cf:03:b5:c0
Note
Once auto connect to mini-C is enabled, you can only access the
mini-C, but not the TCU if you use the serial connection.
To disable auto connect, connect via the LAN interface. Then
type:
tt6194:/$ auto_minic 0
Automatic Mini-C prompt is disabled