Compliance
Automatic Whip Antenna 3040 Installation Handbook 31
EMC and safety notices
Non-ionising radiation safety
To ensure optimal transceiver performance and to avoid
exposure to excessive electromagnetic fields, the antenna
system must be installed according to the instructions
provided.
Safe working distance is based on continuous exposure to
CW-type transmissions, as set out in the ICNIRP Exposure
Guidelines (1998) for occupational exposure. Safe working
distance can be reduced with normal voice communication.
EMC
To ensure compliance with the EMC Directive is maintained,
you must:
1 Use the standard shielded cables supplied from Codan
(where applicable).
WARNING
High voltages exist on the antenna during
transmission and tuning. Do not touch the
antenna during these activities. RF burns may
result.
WARNING
Install the earthing system or counterpoise as
directed to prevent RF burns from any metal
part of the transceiver.
WARNING
You should not transmit from your transceiver
or tune the antenna unless people are beyond the
safe working distance of 1.5 m (5 ft) of any part
of a 3040 Automatic Whip Antenna.