8525B/8528 Technical Service Manual Adjustments 7-15
Publication No: 15-02036 Issue 6
4. Set the called address switches:
• With Options SE2 or SDE fitted—set all the switches in the group
to the digits of the identification number of the station to be called.
• With Options SDEM or SM fitted—set any of the switches in the
group which are not duplicated on the panel. The settings of
switches corresponding to those on the front panel can be
disregarded, e.g. if there are three switches on the front panel, the
1000’s internal switch must be set to the first digit of the group of
numbers which can be called. Other switches can be left at any
setting.
5. Record the code numbers to which the self ident and called address
switches have been set on the frequency label/chart.
6. Re-install the bottom cover by first placing it on the transceiver so that
the front edge rests on the two spring clips. Then press firmly on the
front edge of the cover and slide it forward under the panel surround
until the screw holes are aligned. Resecure with the fixing screws.
7.3.18 Message Length Setting
When a transceiver is to work into a station which uses the selective call
scan facility, the transmitted identification code preamble time must be
extended. This is achieved by the position of a link on P16 as shown in
Figure 7.2.
7.3.19 Selective Call Settings (8528)
Refer to Operator’s Handbook.