EasyManua.ls Logo

Code Alarm caSEC - Page 27

Code Alarm caSEC
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
272017 Voxx Electronics Corporation. All rights reserved.
4 - Trunk Output Timing: Controls the output timing/type of the RED/WHITE Trunk
output.
1 Sec. - 1 second pulse output.
10 Sec. - Continuous output for 10 seconds.
20 Sec. - Continuous output for 20 seconds.
Latched until IGN ON - Continuous output until the vehicle’s ignition is turned
ON.
Latched ON until Button Press - Continuous output until the activation button
is pressed again.
5 - Horn Output Timing: Control the minimum horn pulse time in milliseconds, some
vehicles will require a longer pulse to activate the factory horn.
16mS 10mS 30mS 40mS 50mS
6 - Real Panic: Controls the panic out when triggered from the transmitter.
ON - Randomized horn honks when panic is triggered.
OFF - Standard pattern horn honks when panic is triggered.
7 - AUX 1: Controls the VIOLET/BLACK AUX 1 output activation type and timing.
1 Sec. Pulse - Single 1 second pulse.
Latched - Output stays active until button is pressed again.
Latched until IGN ON - Output stays active until the ignition is turned on.
Dome Light Output - Output is used for illuminated entry and is not controlled
by the AUX 1 function of the transmitter.
8 - AUX 2: Controls the WHITE/BLACK AUX 2 output activation type and timing.
1 Sec. - Single 1 second pulse.
Latched - Output stays active until button is pressed again.
Latched until IGN ON - Output stays active until the ignition is turned on.
10 Sec. w/ Arm - Output stays active for 10 seconds with press of lock button.
10 Sec. w/ Disarm - Output stays active for 10 seconds with press of unlock
button.
L.E.D. Output - OutputwillmimictheashpatternsofthesystemsstatusLED.

Related product manuals