LS1000
Administrator Guide
Code Blue 259 Hedcor Street Holland, MI 4923 USA 800.205.7186 www.codeblue.com Rev 6/2021 page 53 of 57 GU-164-A
5. There are seven Flash Modes and three Steadyburn Modes combinations to choose from.
6. When you reach the desired mode of operation, remove power from the unit. You MUST leave
power disconnected for 20 seconds BEFORE reapplying. When power is reapplied, the unit will
operate as programmed above.
NOTE: If you do not leave power disconnected for 20 seconds before reapplying power, the light will
default to Program Mode.
INPUT VOLTAGE RANGE: 12-24V AC or DC
TEMPERATURE RATING: -40
0
C to +65
0
C (-40
0
F to 149
0
F)
TYPICAL POWER CONSUMPTION AT 25
0
C
Voltage Flash Mode
Steady Mode - High
12V DC
0.24 A Max
0.24 A
24V DC
0.12 A Max
0.12 A
12V AC
1.1 A rms Max
0.53 A rms
24V AC
0.22 A rms Max
0.22 A rms
NOTE: Average current draw in Flash Mode will vary by selected Flash
Mode. The above maximum amperage draw is stated at Single 60 FPM.