4/14/2016
D014465 CR1400 CR1000 CR2300 CR2600 CR3600 CR44X5 CR8000 CR900FD CR6000 CR5000 T500 Client Version ICD
Page 56 of 106
© 2013-2016 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Wide field (FOI 1)
Picture Window Height
Specify height of window used with “take picture.” The
position and size are relative to the virtual image (i.e. not the
rotated physical image).
Note: On a Code Reader, overall image is 960 pixels by 1280
pixels. Upper half is Wide field (FOI 1); lower half is High
Density (FOI 0). The High Density field (FOI 0) does not exist on
the CR900FD.
Keywords: #PictureSettings
Target On Before
Picture (ms)
Valid Range: 0 to 7FFFFFFF Milliseconds
0: Target off before picture capture
Keywords: #PictureSettings
Number Of Retries
Before Reader Gives
Up Sending Packet
Valid Range: 0 to FF Tries
Note: The value 1 is defined as the original send attempt but
no resends. The higher the number the longer each decode
attempt can take.
Keywords: #Communications
Valid Range: 1 to FF (#255) Milliseconds
The Host is requested to poll the USB device at the specified
period.