4/14/2016
D014465 CR1400 CR1000 CR2300 CR2600 CR3600 CR44X5 CR8000 CR900FD CR6000 CR5000 T500 Client Version ICD
Page 74 of 106
© 2013-2016 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default (Hex)
Comment
277
Max Motion Brightness
Percent
3C
(#60)
CR5000:
CR5000RTC:
64
(#100)
Valid Range: 0 to 64 (#100) Percent
The percentage of maximum illumination of the red LED when
used in motion detection.
Keywords: #MotionDetection
278
Low Battery Sleep
Voltage (mV)
0
CR4405:
C1C
(#3100 )
The reader will automatically sleep when the battery voltage is
below this threshold.
Note: Supported on CR4405 only.
Keywords: #Battery
279
Low Battery Sleep
Wakeup Voltage (mV)
0
CR4405:
ED8
(#3800)
If the reader automatically sleeps because of a low battery, it
will wake automatically if the battery voltage goes above this
level.
Note: Supported on CR4405 only.
Keywords: #Battery
27B
Cabled Event
0
CR4405:
E1
(#225)
This event will be triggered when the reader is connected via a
cable.
See register C4 for a list of events
Note: Supported on CR4405 only.
27C
Uncabled Event
0
CR4405:
DE
(#222)
This event will be triggered when the reader is disconnected
from its cable.
See register C4 for a list of events
Note: Supported on CR4405 only.
27D
Phone Connected
Event
DC
(#220)
This event will be triggered when a phone is connected to the
reader.
See register C4 for a list of events
Note: Supported on CR4405 only.
27E
Phone Disconnected
Event
DD
(#221)
This event will be triggered when a phone is disconnected from
the reader.
See register C4 for a list of events
Note: Supported on CR4405 only.