Setting Name
Default (Hex)
Comment
2AF
USB pass-through
mode minimum
battery capacity
percent
5
Valid Range: 0 to 64 (#100) Percent
When in USB pass-through mode, if the sled battery drops to
or below this level, the sled will stop providing power to the
iPhone.
Note: This will cause a communications failure between the
iPhone and the USB host, but it is necessary to prevent sled
reboots that would also cause communications failures.
Note: Supported on CR4405 only.
Keywords: #Battery
2B0
USB pass-through
mode hysteresis
battery capacity
percent
19
(#25)
Valid Range: 0 to 64 (#100) Percent
When in USB pass-through mode, if the sled battery drops
below the USB pass-through mode minimum battery capacity,
the sled battery must reach this higher capacity before power
(and communication) will be restored to the iPhone.
Note: Supported on CR4405 only.