EasyManua.ls Logo

COEF MP250 ZOOM - How to Use the Manual; Technical Notes

COEF MP250 ZOOM
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pag. 4 http://www.coef.it - info@coef.it
This manual has been organized in order support the user, the installer or the maintenance operator of the de
-
scribed unit with those necessary informations for a correct use of the installation and working procedures of the
same unit. The various procedures will be just signalled by indicators (when necessary) evidencing the operation
dangers and the necessity of technical support. Please find here below a list of symbols and relative meaning.
1.0 HOW TO USE THE MANUAL
OPERATOR: Not particulary qualified staff, that can operate when no specific knowledge is required.
COEF OPERATOR Technical staff, qualified and trained by the constructor, for repair and extraordi-
nary operations.
MECHANICAL OPERATORS Staff employed in the ordinary mechanical maintenance.
ELECTRIC OPERATORS: Staff employed in the ordinary electric maintenance.
SPECIALIZED MECHANICAL OPERATOR: Qualified staff employed in extraordinary authorized in-
stallations and repairs.
SPECIALIZED ELECTRIC OPERATORS: Qualified staff employed in extraordinary authorized instal-
lations and repairs.
DANGER SIGNAL Generic danger signal and electric shock danger signal.
MP250 Zoom Code:ZL-012301-01
MSD 250/2 lamp - 250 W - 2.000 hours life - 8.000 °k
540° PAN - 270° TILT
16 bit movement resolution
PAN and TILT automatic repositioning
6 metal and 2 dichroich rotating gobos all interchangeable and indexable on 540°
10 additional metal gobos given with the projector
1 selectable beam reducer
10 colors + white + 8 bi-colors
Rainbow effect adjustable in speed
Black light filter
Linear dimmer from 0% to 100%
Mechanical shutter
Adjustable strobe
4 Lenses optical system
Linear zoom from 12° to 22°
Focus adjustment
Multifunctional display
Remote reset via DMX, selectable from display
Remote ON/OFF lamp via DMX, selectable from display
Software Upgrade via DMX (UNI-PROG 8 optional available)
Internal self-test with led indication
Internal power factor correction - absorbed power 1,4 A.
DMX 512 Standard
8/9 control channels
1.1 TECHNICAL NOTES
v~ Hz I W
100 50 4,3A 382
100 60 3,6A 361
120 50 3,6A 380
120 60 3,0A 359
200 50 2,2A 379
200 60 1,8A 359
230 50 1,7A 380
230 60 1,8A 385
Power supply | Absorbed power