overfilling
(b) Inlet valve fault
(c) Level probe incorrectly
positioned
(b) Check inlet valve
and replace if necessary
(c) Reposition probe
Bearding of ingredient
(a) Extractor fan fault
(b) Steam hoods missing
from mixing bowls or
incorrectly positioned
(a) Check fan
(b) Fit steam hoods to
mixing bowls and
position correctly.
Machine floods
(a) Dispense pipes
incorrectly fitted to
dispense head
(b) Mixing bowls incorrectly
fitted
(c) Whipper seals missing
(d) Overflow pipe
incorrectly fitted
(a) Reposition pipes
(b) Reposition mixing bowls
(c) Check seals
(d) Refit overflow pipe
No display
(a) Display connector loose
(a) Refit connector
TEMP LOW
displayed
(a) Thermal cut-out tripped
(b) Heater fuse blown
(c) Incorrect temperature
(a) Reset cut-out
(b) Check fuse
(c) Check program setting