Name Set/Get Args Range Meaning Description
MIRROR.ANGLE-
POSITION
SET|GET uint8
index
float
α
float
β
[0-63] SET MIRROR.
ANGLE-POSITION 2
10.5 10.5
Get/set the stored angle values corresponding
to the given path position index.
For single axis motion, α or β may be expanded
to +/- 25.000°.
MIRROR.POSITIONS GET GET MIRROR.
POSITIONS
Get the number of positions used in the mirror
path.
Returned value: 0-63.