B/T
®
RAPID-LOAD
®
Peristaltic Pumps and Drive Operating Manual 5-1Cole-Parmer
Section 5 Specifications
Output:
Speed: 11 to 321 rpm
Torque output, Maximum: 1440 oz-in (104 kg•cm)
Speed regulation:
Line ±0.25% F.S.
Load ±0.25% F.S.
Drift ±0.25% F.S.
Display: Four-digit, seven segment LED
Remote outputs:
Voltage speed output (0–10V DC)
Current speed output (0–20 mA or 4–20 mA)
Tach output (TTL, 128 to 7680 Hz)
Motor running output (N.O. & N.C. contact closure)
Tubing Compatibility: Sizes B/T 87 or B/T 91
Flow Range: up to 10 GPM (37.85 LPM)
Input:
Supply voltage limits:
77111-40 90 to 130 Vrms @ 50/60 Hz
77111-47 200 to 260 Vrms @ 50 Hz
Current, max.:
77111-40 6.5A
77111-47 3.3A
Remote Inputs: Start/Stop, CW/CCW, PRIME (contact closure)
Voltage input (0–10V DC)
Current input (0–20 mA or 4–20 mA)
Construction:
Dimensions (L × W × H):
77111-10, 77111-15 9 in × 11 in × 4 1/2 in
(229 mm × 279 mm × 114 mm)
77111-12, 77111-17 28.25 in × 15.88 in × 15.13 in
718 mm x 403 mm x 384 mm
Weight:
77111-10, 77111-15 9.4 lbs (4.3 kg)
77111-12, 77111-17 89.0 lbs (40.37 kg)
Enclosure Rating: IP 56 (NEMA 4) Per IEC 60529
Models 77111-10
77111-12
77111-15
77111-17
77111-40
77111-47