REGULATOR RESET PROCEDURE
If you are experiencing any of the following performance issues, you may have activated the flow
limiting feature in your regulator:
Burners not getting hot enough.
Low or incomplete burner flames.
Low gas pressure.
Difficulty lighting all burners or burners not staying lit.
Before disconnecting the LP cylinder:
1. With all control knobs in the “OFF” position and the cylinder shut-off valve in the “OFF”
position, open the barbecue lid.
2. Disconnect the regulator from the LP cylinder.
3. Turn all control knobs to the “HI” position, and let stand for 1-3 minutes,
allowing all excess gas in the gas manifold to dissipate.
4. Turn all control knobs back to the “OFF” position.
5. With the barbecue lid still OPEN, reconnect the regulator to the LP cylinder.
Do not cross thread the connection. Hand-tighten only.
6. Check all connections to ensure that a positive seal has been made.
7. Slowly open the LP cylinder shut-off valve.
8. Wait approximately 30 seconds for the regulator pressure to stabilize.
9. Turn the first control knob to the “HI” position.
10. Press the electronic ignition button, or use a match and the match holder,
or a barbecue lighter to ignite the burner.
NOTE: If the LP cylinder is opened too quickly, the flow limiting device in the regulator will activate,
limiting the flow of gas from the LP cylinder. the system.
NOTE: Avoid activating the flow limiting feature in the regulator by following the proper lighting and shut
down procedures and performing a complete leak test and safety check to ensure that there are no leaks in
the system.