INSTRUCTION MANUAL FOR DISHWASHERS
Page 7 of 10
GB
4.7 Removal of integral filter
1. Turn off the machine.
2. Place the wash and rinse arms at a right angle to the edge
of the door
(
Fig.5
).
3. Raise each semi-filter, grasping it by the handle.
4.8 Emptying the machine
4.8.1 Machine without drain pump
¾ Turn off the machine.
¾ Remove the integral filter (
Fig.5
).
¾ Extract the overflow by pulling upwards (
Fig.6 B
), and wait for the tub to drain
completely.
If necessary, extract the tub filter and clean (
Fig.6 C
).
4.8.2 Machine with drain pump
¾ With the machine on (
Fig.7
), press the PROGRAMME SELECTION button (2)
until the
DRAIN CYCLE indicator light (5) comes on.
¾ Remove the integral filter(
Fig.5
).
¾ Extract the overflow (
Fig.6 B
).
¾ Press the START button (3). Machine draining starts and the indicator light flashes.
¾ The machine turns off at the end.
If necessary, extract the tub filter and clean (
Fig.6 C
).
4.9 Resin regeneration
In machines with internal softener (available on request), when the REGENERATION indicator
light
(8) flashes rapidly
(
Fig.8
), you need to run a resin regeneration cycle to restore proper
operation of the internal softener.
Proceed as follows:
Empty and clean the machine.
Open the salt container of the tub after removing the integral filter.
Pour approx. 300 g of regeneration salt into the container (kitchen salt without additives in 1 or
2-mm diameter granules).
Close the container again firmly.
Make sure that the overflow has been removed.
Close the door and turn on the machine.
Use the PROGRAMME SELECTION key (2) to select the resin regeneration cycle (the
REGENERATION indicator (8) turns green
).
To start the cycle, press the START button (3) (the REGENERATION light (8) flashes
). The
regeneration cycle starts and continues for about 20 minutes .
The machine turns off when the cycle ends.