CALOR 40 Manual Page 26 (total 27) COMAC CAL s.r.o.
Factory settings
In the case that the customer does not provide the parameters to some settings of the meter,
the configuration will be carried out according to the following table:
Diameter
nominal
Limits set for 4 ÷ 20 mA current loop
Performance monitoring
Monitoring of flow rate within A
range
Monitoring of flow rate within B
range
DN
Pmin4÷20 [kW]
Pmax4÷20 [kW]
Qmin4÷20 [l/h]
Qmax4÷20 [l/h]
Qmin4-20 [l/h]
Qmax4÷20 [l/h]
6
0
100
6
1200
20
1200
8
0
150
11
2200
40
2200
10
0
250
17
3400
60
3400
15
0
500
38
7600
130
7600
20
0
1000
71
14200
240
14200
25
0
1500
105
21000
350
21000
32
0
2500
170
34000
600
34000
40
0
3500
270
54000
900
54000
50
0
6000
420
84000
1400
84000
65
0
10000
720
144000
2400
144000
80
0
15000
1100
220000
3600
220000
100
0
25000
1700
340000
5600
340000
150
0
50000
3800
760000
13000
760000
200
0
90000
6800
1350000
23000
1350000
300
0
200000
15300
3052000
51000
3052000
Diameter
nominal
Pulse constants
Output
Input
DN
Eout[MJ/pulse]
Vout[l/pulse]
In1 [pulse/l]
In2 [pulse/l]
6
1
1
1
1
8
1
1
1
1
10
1
1
1
1
15
1
1
1
1
20
1
1
1
1
25
1
1
1
1
32
10
10
1
1
40
10
10
1
1
50
10
10
1
1
65
10
10
1
1
80
10
10
1
1
100
100
100
1
1
150
100
100
1
1
200
100
100
1
1
300
100
100
1
1
Time tariffs
Set periods
1
6:00 - 14:00
2
14:00 - 22:00
3
22:00 - 06:00
The meter's address is set to 1 and the communication baud rate to 1200 Bd.