TROUBLESHOOTING
INSUFFICIENT WATER ON THE BRUSHES
1. Check the tap is turned on
2. Check the solenoid valve switch is on
3. Check there is water in the solution tank (“RESERVE” indicator light off)
3
1
2
4. Clean the solution filter
THE MACHINE DOES NOT CLEAN WELL
1. Check the state of wear and tear of the brushes and, if necessary, replace them
(the brushes must be replaced when the bristles are about 15mm long).
2. Check the brush pressure is sufficient and, if necessary, increase it (see “BRUSH
PRESSURE” in the chapter “WORK”)
3. Use a different kind of brush to the one fitted as standard. For cleaning floors where
the dirt is particularly resistant, we recommend the use of special brushes supplied
upon request and according to needs (see “CHOOSING AND USING THE
BRUSHES”).
THE SQUEEGEE DOES NOT DRY PERFECTLY
1. Check the squeegee is clean
2. Adjust the height of the squeegee support (see “MACHINE PREPARATION”)
3. Clean the entire suction unit (see “WEEKLY MAINTENANCE”)
4. Replace the rubbers, if worn