Chapter 4: Fault Finding and Test Procedure
FAULT FINDING
Indication
Possible Fault
Solution
Power to the unit has been
switched ON but no lights
are on.
No power from the DB.
Check the circuit breaker to
ensure that it is ON.
Faulty line between DB and
the unit.
Check the power line to the
unit to ensure that it is
working.
Faulty surge protector.
Check the surge protector.
Faulty transformer.
Check the switch mode
power supply.
The power from the DB is in
working order but there is no
light on the surge protector.
Faulty surge protector.
Replace the surge protector.
Light on at the surge
protector but no lights on at
the PCB.
Faulty transformer.
Replace the switch mode
power supply.