17
SPECIFICATIONS AND TECHNICAL DATA
CAUTION
• For the engine to reach its maximum power it needs at least 10 hours running-in at a load 15 to 20%
lower than the machine’s maximum performance.
• The engine’s maximum power diminishes as the altitude and ambient temperature at which it is
working increases (there is a drop of about: 3.5% every 305 m/1000 ft above sea level and 1% every
5.6°C/42°F above 16°C/61°F). If the high pressure water cleaner is used at a high altitude or with high
ambient temperature please refer to the engine’s operating and maintenance manual to see if any
precautions need to be taken.
• The declared performance refers to an atmospheric pressure of 1013 hPa at sea level and an ambient
temperature of 16°C/61°F.
• If the high pressure cleaner is not connected to the water mains but takes water from a tank, in certain
conditions the thermostat valve can open and prevent the complete self-priming of the pump. In
these cases, t a rubber hose into the hose connection of the thermostatic valve and bring the other
end of the hose to the tank from where the pump takes the water.
• The specications and technical data are approximate. The manufacturer reserves the right to make
all changes to the machine it deems appropriate.
FDXXtreme
(1)
18/350 21/500 15/500 18/400 21/350 30/280 36/230 42/180
MOTORISATION
BS 18hp BS 31hp Honda GX 690
Fuel
Petrol
Power
(kW - HP)
15,0 - 18,0 23,0 - 31,0 16,4 - 22,0
Nominal rotation speed - maximum
(RPM)
3400 – 3600 [1560 – 1650
(*)
]
HYDRAULIC CIRCUIT
Maximum supply water temperature
(°C - °F)
60 – 140
Minimum supply water temperature
(°C - °F)
5 – 41
Minimum supply water ow rate
(l/min - USgpm)
23 - 6,1 27 - 7,1 20 - 5,3 23 – 6,1 27 – 7,1 39 – 10,3 47 – 12,4 55 – 14,5
Maximum supply water pressure
(bar - psi)
8 – 116
Maximum priming depth
(m - ft)
0 – 0 1,0 – 3,3
PERFORMANCE
Maximum ow rate
(l/min - USgpm)
18 - 4,8 21 - 5,5 16,5 – 4,4 18 – 4,8 21 – 5,5 30 – 7,9 36 – 9,5 42 – 11,1
Nominal ow rate
(l/min - USgpm)
17,5 - 4,7 20,5 - 5,4 15 – 4,0 17,5 – 4,7 20,5 – 5,4 29,5 – 7,8 35,5 – 9,4 41 – 10,8
Maximum pressure
(bar - psi)
360 - 5220 520 - 7540 520 – 7540 415 – 6020 360 – 5220 280 – 4060
230 – 3335
180 – 2610
Nominal pressure
(bar - psi)
350 - 5075 500 - 7250 500 – 7250 400 – 5800 350 – 5075 270 – 3915 220 – 3190 170 – 2470
Maximum reaction force on the spray gun
(N)
79 110 78 83 91 115 124 127
Sound pressure level - Uncertainty
(dB(A))
89 – 0,7
(2)
89 – 0,7
(3)
89 – 0,7
(2)
Sound power level
(dB(A))
107
(2)
107
(3)
107
(2)
Operator hand-arm vibration - Uncertainty
(m/s
2
)
3,9 – 0,24
(2)
3,9 – 0,24
(3)
3,9 – 0,24
(2)
PUMP OIL
MULTITECH
THT
(4)
15W–40
(4)
ENI MULTITECH THT
(4)
GEARBOX OIL
80W–90
(4)
WEIGHT AND DIMENSIONS
Length x width x height (mm - in)
(mm - in)
1000 x 820 x 850 – 39,4 x 32,3 x 33,5
Weight
(kg - lb)
145 - 319,7 155 - 341,7 150 - 330,7
EN
WARNING
TRANSLATION OF THE ORIGINAL INSTRUCTIONS
Read and keep in mind that indicated in the
INSTRUCTION
MANUAL SAFETY WARNINGS.
EN