STORAGE
• Wind up the high pressure hose (35) with due care, making sure it is not bent. For products without a
hose reel, hang it up on its support (10).
• Wind up the power cord (6) and hang it up on its support (10).
• Store the high pressure cleaner in a clean, dry place. Make sure the power cord and the high pressure
hose are not damaged.
ROUTINE MAINTENANCE
Follow the instructions for
“STOPPING WORK”
and those provided in the table below.
MAINTENANCE
SCHEDULE
ACTION
Every time the cleaner
is used
• Check the power cord, the high pressure hose, the connectors, the cleaner
gun and the lance pipe.
Should any of these look damaged, do not use the cleaner for any reason
and contact a
QUALIFIED TECHNICIAN
.
Once a Week • Check the water inlet lter (18) and clean it if necessary.
Use a coin (Fig. 1 and 2) to turn the screw (37) anticlockwise and lower the
door(33).
Unscrew the cup (62) and take the lter cartridge (61) out.
Running water or compressed air is generally all that is needed to clean
the lter cartridge. In dicult cases, use a lime scale remover or replace the
lter cartridge. For tough cases, use a lime scale remover or replace it by
contacting a
QUALIFIED TECHNICIAN
to buy the spare part.
Replace the lter and put the cover back, following the above steps in reverse
order.
Once a Month • Clean the nozzle.
To clean the nozzle, it is generally sucient to insert the pin (31) supplied
into the nozzle’s hole. If no appreciable results are obtained, contact a
QUALIFIED TECHNICIAN
to buy the spare part . The nozzle can be replaced
using a 14mm/0.55” spanner (not supplied).
• Clean the detergent suction lter(58).
It is normally enough to put the lter under running water or blow it with
compressed air to clean it. In the more dicult cases use a water softener
or replace it, contacting a
SPECIALIZED TECHNICIAN
to buy a new one.
• Check the pump oil level.
Use the dipstick (51) (Fig. 2). If you need to top up the oil, contact a
QUALIFIED
TECHNICIAN.
• Cleaning the fuel ll up lter (59).
Unscrew the fuel tank cap (7) to reach the ll up lter. Take the lter out and
remove any impurities. In the more dicult cases replace it, contacting a
SPECIALIZED TECHNICIAN