4 INSTALLATION
See Fig. 2 at the front of these operating and maintenance instructions.
4.1 ASSEMBLING THE ACCESSORIES
a) Assemble the xed fan-like jet professional nozzle (20) on the nozzle-holding head (18), by
tightening well with a 14-mm socket wrench (not supplied). Operation A of Fig. 2.
b) Screw the end of the high-pressure hose (7) (side without fast coupling for CLASSIC) on the
water gun thread (16) and tighten well with two open end 17-mm wrenches (not supplied).
Operation B of Fig. 2.
c) Engage the lance hose (17) onto the water gun (16) and screw well. Operation G of Fig. 2.
d) Unwind the high-pressure hose (7), insert the fast-coupling connector (22) onto the water outlet
connector (6), screw and tighten the ring nut by hand (only CLASSIC). Operation C of Fig. 2.
e) Insert the water suction lter/gasket (33) into the water inlet connector (1), by paying attention
to position the projecting side of the lter inside the connector and screw well the water suction
connector (35). Operation D of Fig. 2
4.2 CHECKS AND CONNECTION TO THE MAINS WATER SUPPLY
WARNING
The water supply must be able to guarantee the adequate delivery of water ow to the high
pressure cleaner; refer to the table of technical specications.
In case of doubt, contact a Skilled Technician.
Do not supply the water cleaner with water at a temperature in excess of 40°C/104°F or below
5°C/41°F.
The pressure of the water supply must not be in excess of 8 bar/116 psi.
Do not operate the high pressure cleaner with a priming depth in excess of 0 m / 0 ft.
Do not operate the high pressure cleaner if it is not connected to a water supply.
Do not supply the high pressure cleaner with salt water or water containing impurities. In this
event, run the high pressure cleaner for a few minutes with clean water.
« CAUTION
Follow current regulations for connection to the mains water supply in the country where the
water cleaner is installed.
4.3 CHECKS AND CONNECTION TO THE MAINS ELECTRICITY SUPPLY
« CAUTION
A Skilled Technician must check that the electrical supply complies with the data indicated
on the identication label (12) on the high pressure cleaner. It is especially important that the
supply voltage does not differ more than +-5% from that indicated on the label.
All connections to mains electricity must be carried out by a Qualied Eletrician according to
IEC 364 regulations or the equivalent standard in the country where the high pressure cleaner
is to be used. It is especially important that the current outlet where the high pressure cleaner is
connected is provided with an earth conductor and a suitable fuse (according to the size indicated
on the identication label and in the table of technical specications), and must be protected by
a magneto-thermal differential circuit breaker, whose sensitivity is not in excess of 30 mA.
WARNING
This appliance must be earthed.