When the water cleaner is not in use, do not leave its plug in the power outlet and disconnect
it before any activity. More precisely, make sure that the mains switch (2) is in position “0”,
remove the plug from the power outlet, press the lever (24) on the cleaner gun to eliminate
any remaining pressure and bring the safety catch in its locked position (25) (Fig. 1 position
S):
- before leaving the high power cleaner unattended, even for only a short time;
- after use;
in addition, wait until the high pressure cleaner has completely cooled down before cleaning
or maintenance.
During use, do not lock the lever (24) on the cleaner gun in the open position.
Do not remove the plug from the power outlet by pulling on the power supply cable.
Do not put any reducers or adaptors between the electric plug and the power outlet.
Keep the power supply cable, any extension cords, the plugs and the outlets dry. Do not touch
them with wet hands.
If the supply cord is damaged, it must be replaced by the Manufacturer or by a Skilled
Technician, in order to avoid a hazard.
If, due to any reasons, the plug is cut from the power supply cable, there is the risk of electrical
shock in case it is inserted in any home socket. To avoid this ranger, it is necessary to immediately
eliminate the cut plug.
If the device is equipped with a 13 A plug conforming to standard BS 1363, it is necessary to
observe what follows:
- do not use the device if the fuse cover is not present: in case it was lost, the spare cover can
be ordered to the service centre
- replace the possibly burnt fuse only with a 13 A ASTA approved fuse according to standard
BS 1362; to replace the fuse, in case of doubts, apply to a Skilled Technician or to a Qualied
Electrician;
- reposition the cover in the correct way after replacing the fuse.
Use only gas oil for motor driving. The use of any other fuel can be dangerous.
During the operation, do not cover the water cleaner and do not place it where its ventilation
could be impaired; never cover the stack (28) emitting the boiler exhaust gases.
When you use the water cleaner in closet environments, make sure that the exhaust gases are
evacuated in the correct way and that there is a correct ventilation (poisoning danger).
Never bend onto the stack (28), nor touch it with bare hands (burning danger).
WARNING
If you use the water cleaner at room temperature that is higher than 40 °C/104 °F, do not let
it directly under the sun.
If the water cleaner is used beyond 1000 m/3280 ft of height, apply to a Skilled Technician
for a check and a possible combustion adjustment.
5.1 PRELIMINARY PROCEDURES
Unroll the high-pressure pipe (7) completely.
If you have a model equipped with hose reel (4), unlock the device by rotating the ring nut in
counter-clockwise direction (3); unwind the hose quantity that you need, by rotating it in counter-
clockwise direction by using knob (5); lock the device by rotating the ring nut (3) in clockwise
direction.
Fix a supply hose having an inner diameter of 18 mm/0.7 in. to the water suction connector (35),
by tightening with a suitable collar clamp. Operation D of Fig. 2.
Open the water supply tap, by paying attention that there is no dropping.
Operation E of Fig. 2.