16. Error Messages
Error Code
Fault
Action
Err 3
No price or pump number set.
Set the pump number or:
Set a price at the pump or at
the controller.
Err 7
Excess flow.
Max Flowrate exceeded
Err 8
Excess reverse rotation of encoder.
Check product is not flowing
back into the tank once the
delivery has finished.
Err 9
Faulty or disconnected meter encoder.
1. Check that encoder is
plugged in.
2. Replace encoder PCB on
meter
Err 10
Configuration Lost
Reconfigure C4000 refer to
C4000 manual
Err 12
C4000 memory failure.
Change memory IC.
F-AD-DS1225 (not applicable
to Futra)
Ped
Abd
Display error
1. Check display cable for
loose wires/crimps
2. Replace display PCB