Fixed Disk 0 or 1 Failure Parity Check 1 System RAM Failed at Offset
Fixed Disk Controller Failure Parity Check 2 System Timer Error
Incorrect Drive A Type Real Time Clock Error UMP Upper Limit Segment
Invalid NVRAM Media Type System Battery is Dead Video BIOS Shadowed
POST Messages
Error Message Probable Cause Recommended Action
Disk Drive A Error Drive A is present, but fails the
BIOS POST disk tests.
Run Setup.1.
Replace the signal cables.2.
Replace the disk drive.3.
Extended RAM failed at offset
nnn
Extended memory not working
or not configured properly.
Replace the memory
modules.
1.
Replace the system board.2.
Failing Bits nnn nnn is a map of the bits at the
RAM address which failed the
memory test.
Run Setup.1.
Replace the system board.2.
Fixed Disk 0 or 1 Hard drive is not working or not
configured properly.
Run Setup.1.
Replace the system board.2.
Fixed Disk Controller Failure Hard drive is not working or not
configured properly.
Run Setup.1.
Replace the system board.2.
Incorrect Drive A Type Type of disk in drive A not
correctly indentified.
Replace the memory
modules.
1.
Replace the disk drive.2.
Invalid NVRAM Media Type Problem with NVRAM (CMOS)
access.
Replace the system
board.
Return to top

Table of Contents