EasyManua.ls Logo

Comtech EF Data XTD-400C - Page 106

Comtech EF Data XTD-400C
158 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPENDIX A
THIS DOCUMENT IS THE PROPERTY OF XICOM TECHNOLOGY. REPRODUCTION OR RELEASE WITHOUT EXPRESS PERMISSION IS STRICTLY PROHIBITED.
XTD-400C, 5.85 – 6.425 GHz, RO1
Document No. 305-0386-201 REV 2 Page 10 of 11
Spec
Paragraph
No
Test Description Test Condition Requirements Units
Measured
Performance
Pass
or
Fail
Min
Max
3.1.1 &
3.1.4.1
3.1.4.1.2
3.1.4.1.3
Spurious Signals
Note 3.
-37 dBc max
10 to 10,000 Hz
(-20(1.5 + log(f)) +13) dBc
max
10-100 kHz
-60 dBc max
>100 kHz
Power Line Related:
50 dBc max
line related individual
-47 dBc max
sum of all
STD
Freq = 6.1375 GHz
V
in
= 100 VAC
P
o
= 50.4 dBm
Span = 2 KHz
N/A
Note
3
dBc
See attached
plot
Pass
Fail
Span = 20 KHz N/A
Note
3
dBc
See attached
plot
Pass
Fail
Span = 200 KHz N/A
Note
3
dBc
See attached
plot
Pass
Fail
Span = 2 MHz N/A
Note
3
dBc
See attached
plot
Pass
Fail
Span = 20 MHz N/A
Note
3
dBc
See attached
plot
Pass
Fail
Span = 200 MHz
N/A
Note
3
dBc
See attached
plot
Pass
Fail
3.1.1 &
3.1.14.4
Out of Band Spurious
LO+2IF = 6.8 GHz
STD
Freq. = 5.85 GHz
V
in
= 100 VAC
P
o
= P
rated
3 dB
N/A -60 dBc
See attached
plot
Pass
Fail
Freq = 3.625 to 4.200
GHz
N/A -60 dBc
See attached
plot
Pass
Fail
* referenced to measured small signal gain across the band
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.

Table of Contents