4-40 l Oper a tion
When configured as a
central dryer, the high
setpoint limits can not
be set since there is no
process heater in the
system.
Central
Setting the High Setpoint Limit
You can protect your drying process by preventing someone from entering process
temperatures above or below an acceptable level for the material. You can also set
the high and low limits equal to the process temperature to prevent accidental or
unauthorized changes to the setting during operation.
1 Turn on the main power to the dryer.
2 Use the Scroll keys to access the SETUP, PROC, PROC, and PROC
screens under the Dryer Main Menu, screen 12.
SCREEN 36 SCREEN 37
SCREEN 38 SCREEN 14
3 Then select the PROCESS TEMPERATURE RANGE screen.
SCREEN 39
4 The PROCESS TEMPERATURE RANGE screen shows the
allowable temperature range for setpoint temperatures. With the
supervisory password this range can be narrowed. See page 4-31,
screen 85.
DRYER SETUP
PROC ALM DISP OTHER
SETUP PROCESS
PROC REGEN OTHER
PROCESS TEMPERATURE
RANGE 100 F - 450 F
SETUP PROCESS
PROC PROPID RETPID
DRYER PROCESS
SETUP SCREEN
NOTE: Software may allow
the Process temperature
setpoint limit up to 450
°F,
however Conair does not
recommend a setpoint limit
over 375
°F {191°C} due to
nuisance alarms.
✐
NOTE: To avoid nuisance
alarms Conair recommends
that the low setpoints to be
set to 150
°F {66°C} or
above.
✐