SPECIAL NOTES FOR THIS RADIO
Firmware Bug
The first released version of the radio is 1.0.5. This version has one
known problem at this time (12/2/16) in that the Enhanced Parameter
Mode does not work if you are using Group Calling. It does work if
using private calling. Check our website at www.connectsystems.com
for updated firmware.
Two Way Communication
If you want to have two-way conversation with this radio, you must
populate the Rx Contact field in the Channel section of the radio.
Typically, the Rx Contact and the Tx Contact are identical.
Defaults
This radio is shipped with the following defaults. They can be changed
with the CPS
Scanning Frequency: 442 MHz - 450 MHz, Rx Freq = Tx Freq – 5Mhz
Channel 1: Analog, Wide Band
Channel 2: Digital, Group Call, Color Code 1 and Slot 1
Channel 3: Digital, Group Call, Color Code 1 and Slot 2
Channel 4: Digital, Private Call, Color Code 1 and Slot 1
Channel 5: Digital, Private Call, Color Code 1 and Slot 2
Important Non Obvious Notes
When scanning analog signals, have the channel on any analog
channel before going into the Enhanced Scanning Mode.
When scanning digital signals, have the channel on any digital
channel before going into the Enhanced Scanning Mode.
When going into the Enhanced Monitor Mode for analog signals,
first set the channel to an analog channel.
When going into the Enhanced Monitor Mode for digital signals,
first set the channel to a digital channel.