June 2018
SD One+/MF Work Instruction
Tools required:
T10 screwdriver
T20 screwdriver
Prerequisite
Disconnect power from the scanner.
Re-positioning the Lid Sensor
1. Follow this procedure if the Lid
Sensor is not working correctly
and it is visibly not central in the
chassis.
2. Depress the latch levers at both
ends of the scanner.
NOTE: This work flow is exactly the same for the SD
One+ and the SD One MF, unless otherwise indicated.
3. Raise the CIS Bridge Unit.
4. Remove screws (3 x T20) in both
ends of the CIS bridge.
5. Open the CIS Bridge.