ANNUAL MAINTENANCE:
A kit n°450201 suitable for the following operations, is available for sale.
Change the pump inlet filter (No. 411861)
On the Steam boiler:
o Change vacuum valve (No. 408898)
o Change the safety valve (No. 404326)
On the coffee boiler:
o Clean the draining valve core.
On the inlet bloc valves:
o Change the filter (No. 470199)
o Replace the gasket (No. 219000) of 2 non-return valves.
o Remove and clean the gasket limiter 12 Bars (1,2 MPa)
o Clean the nucleus of the solenoid inlet water boiler.
On the mixer cold-water valve:
o Clean both cold water valves cores
On the pre-brewing valve:
o Clean the pre-brewing valve core.
On the coffee group:
o Change the O-ring nozzle (No. 403457) and the filter nozzle (No. 403458)
o Clean the 3rd way and the nucleus of the solenoid coffee valve.
On the hot water valve:
o Clean the nucleus of the solenoid "hot water" valve.
On the Steam tap:
o Change the 2 O-rings (No. 403457)
o Change the 1 gasket (No. 407502)
On the "steam" output and on the "hot water" output
o Change the O-ring (No. 061200)
o Change the O-ring (No. 055300)
For water quality issues, it is recommended to fully drain the boiler.