www.rinnai.us
Model V2532W2
SPECIFICATIONS
Type of appliance Temperature controlled continuous flow gas hot water system
Operation With / without remote controls, mounted in kitchen, bathroom, etc.
Exhaust system Direct Vent - Forced combustion
Rinnai model number REU-V2532W-US
Maximum/Minimum gas rate (Input BTU's)
199,000 BTU's - 15,000 BTU's Natural Gas
199,000 BTU's - 15,000 BTU's Propane Gas
Thermal Efficiency Natural Gas: 84% Propane: 85%
Energy Factor (EF) Natural Gas: 0.82 Propane: 0.84
Capacity (Gallons 1st Hour @ 90°F rise) Natural Gas: 218 Propane: 227
NO
x
Emissions (at 3% O
2
) less than 40 ppm
Hot water capacity, (50°F rise) 0.5 to 6.5 GPM
Maximum hot water capacity, (35°F rise) 8.5 GPM
Setpoint Temperature (without remote) Factory setting - 120°F
Temperature range with optional remote
Keypads connected
MC controller : 96 - 140°F
BC and BSC controller : 96 - 120°F
Approved gas type Natural or Propane - Ensure unit matches gas type it's being installed on.
Installation Outdoor Installation Only
Dimensions
Height 23 5/8"
Width 13 3/
4"
Depth 8 7/
8"
Weight 46 Lbs.
Connections
Gas supply 3/4" MNPT
Cold water inlet 3/4" MNPT
Hot water outlet 3/4" MNPT
Ignition system Direct electronic ignition
Electrical consumption
Normal 63 watts
Standby 5.5 watts
Anti-frost protection 84 watts
Water temperature control Simulation feedforward and feedback.
Water flow control
Water flow sensor, electronic water control device, and electronic by-pass
control device
Recommended Minimum water
supply pressure
20 PSI (Rinnai recommends 50-80 PSI for maximum performance)
Maximum water supply pressure 150 PSI