EasyManua.ls Logo

Copland CVA306 - Maintenance and Specifications; Maintenance Recommendations; Warranty and Service Information; Technical Specifications

Copland CVA306
5 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
Maintenance
The amplifier is build for a long lifetime, and no special care needs to be taken apart
From what is already described under installation. However the heart of the amplifier
Is the Valves / Tubes and like a light bulb, they have a limited lifetime and can therefore
after a period affect the performance of the amplifier. You should therefore after 4000
playing hours, or if the amplifier changes sound, contact your service agent for replace-
ment of valves.
Warranty and Service
Copland provides a warranty to the first purchaser for a period of one year that the
amplifier will work perfectly. Copland usually commissions the Copland agency in the
country in which the amplifier was purchased to carry out any warranty work.
Following consent from Copland in a particular case, the warranty service may also
be claimed at an agency in another country.
Specifications
Vacuum tubes 12AX7 / ECC83 (6)
Output voltage Rated 2V. max.15V
T.H.D. Less than 0,1% (output 1V)
Input sensitivity 300mV (output 1V )
Input impedance 25 K ohms
Output impedance Less than 600 ohms
S/N ratio (IHF-A curve) More than 90 dB
Power consumption 40W
Nominal mains voltage 115V or 230V factory set for destination country only
Mains voltage range +/- 12%
Dimensions 430(W) 110(H) 390(D)
Shipping weight 10 Kg

Related product manuals