Loading...
35
Inhibit
d12: First or Second
Acceleration/deceleration Time
Selection
d13: Base-Block (B.B.) (N.O.)
d14: Base-Block (B.B.) (N.C.)
d15: Increase Master Frequency
d16: Decrease Master Frequency
d17: Run PLC Program
d18: Pause PLC
d19: Counter Trigger Signal
d20: Counter Reset
d21: Select ACI / Deselect AVI
d22: Disable PID function
d23: JOG FWD
d24: JOG REV
d25: The source of master frequency is
AVI.
d26: The source of master frequency is
ACI.
4-09
Line Start Lockout
d0: Disable
d1: Enable
d0
4-10
Up/down frequency command
mode
d0: Up/down frequency by
acceleration/deceleration time
d1: Up frequency according to constant
speed, down frequency according to
deceleration time
d2: Up frequency according to
acceleration time, down frequency
according to constant speed
d3: Up/down frequency by constant
speed
d3
4-11
Acceleration /Deceleration speed
of constant up/down frequency
d0 to d1000 Hz/sec
d1
Group 5 Multi-Step Speed and PLC Parameters
5-00
1st Step Speed Freq.
d0.0 to d400 Hz
d0.0
d1
5-01
2nd Step Speed Freq.
d0.0 to d400 Hz
d0.0
d10
5-02
3rd Step Speed Freq.
d0.0 to d400 Hz
d0.0
d1
5-03
4th Step Speed Freq.
d0.0 to d400 Hz
d0.0
5-04
5th Step Speed Freq.
d0.0 to d400 Hz
d0.0