36
5-05
6th Step Speed Freq.
d0.0 to d400 Hz
d0.0
5-06
7th Step Speed Freq.
d0.0 to d400 Hz
d0.0
5-07
PLC Mode
d0: Disable PLC Operation d1: Execute
one program cycle d2: Continuously
execute program cycles d3: Execute
one program cycle step by step d4:
Continuously execute one program
cycle step by step d5: Disable PLC
operation, but can set direction of 1st
speed to 7th speed
d0
5-08
PLC Forward/ Reverse Motion
d0 to d255 (0: FWD 1: REV)
d0
5-09
Time Duration Step 0
d0 to d65500 Sec
d0
5-10
Time Duration Step 1
d0 to d65500 Sec
d0
5-11
Time Duration Step 2
d0 to d65500 Sec
d0
5-12
Time Duration Step 3
d0 to d65500 Sec
d0
5-13
Time Duration Step 4
d0 to d65500 Sec
d0
5-14
Time Duration Step 5
d0 to d65500 Sec
d0
5-15
Time Duration Step 6
d0 to d65500 Sec
d0
5-16
Time Duration Step 7
d0 to d65500 Sec
d0
Group 6 Protection Parameters
6-00
Over-Voltage Stall Prevention
d0: Disable
d1: Enable
d1
6-01
Over-Voltage Prevention Level
230V series: d350 to d410V
460V series: d700 to d820V
d390
d780
6-02
Over-Current Stall Prevention
Level
d20 to d150%
d130
6-03
Over-Torque Detection Mode
d0: Disabled
d1: Enabled during constant speed
operation and continue to run to OL1 or
OL.
d2: Enabled during Constant Speed
Operation and halted after detection
d3: Enabled during running and
continues before Continuous Output
Time Limit (Pr.6-05) is reached
d4: Enabled during running and halted
after Over-Torque detection
d0
d2
6-04
Over-Torque Detection Level
d30 to d200%
d150
d50
6-05
Time setting for Over-torque
Detection
d0.1 to d10.0 Sec
d.01
d1