ET 66 - ET 66 M operator’s manual
GB
NOTES
- At the end of the calibration routine remove the reference weight from the wheel.
- If you wish to interrupt the self-calibration program at any time simply press
and
you will return to the previously selected program.
- THE ABOVE CALIBRATION PROCEDURE IS VALID FOR ALL TYPES OF TRUCK
WHEELS.
CALIBRATION PROGRAM FOR
CAR WHEELS
This operation must be performed when you feel that the machine is out of tolerance
or when it calls for self-calibration by displaying the message Err CAL on the display
when it is set up for car wheels.
- Set the machine in car balancing mode (LED next to CAR is lit).
- Mount an average size and balanced car wheel (or one with fairly limited unbal-
ance)
- Input all the wheel data accurately
- Press the
keys until the LED next to CAL lights.
- Confirm with
.
- Proceed as described above for truck wheel calibration but in this case use a 100 g
(3.5 oz) standard reference weight.
- THE ABOVE CALIBRATION PROCEDURE IS VALID FOR ALL TYPES OF CAR
WHEELS.
Грузик - все для шиномонтажа www.gruzik.com.ua