EasyManua.ls Logo

Corghi ET 66 - Electrical Hook-Up

Corghi ET 66
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ET 66 - ET 66 M operator’s manual
GB
NOTE FOR ET 66
If the machine is supplied with a kit for connection to an external 12V power source, fit
the relevant connection cable as described below (see fig.5):
- remove the plastic weight tray;
- insert the cable connector from the outside toward the inside through the largest
hole on the outside of the cabinet;
- remove connector Jsb from the card and in it place connect the connector from the
kit;
- secure the power socket on the cabinet together with the change-over switch;
- refit the weight tray;
- set the change-over switch to either network or battery (N, fig.4), according to
intended use;
- if you are using an external power source, connect one of the supplied cables to the
socket (M, fig.4) for hook up to a battery or cigar-lighter socket.
To terminate the installation procedures the machine must be calibrated (see calibra-
tion heading).
ELECTRICAL HOOK-UP
On request, the balancer can be set up by the manufacturer to operate with the power
supply available in the place of installation. The set-up details for each individual
machine are given on the machine data plate and on a special label attached to the
power supply connection lead.
NOTE FOR ET 66
If the machine is to be used exclusively with the external battery it is not necessary to
connect it to the mains network.
WARNING
All electrical hook-up operations must be carried out exclusively by a qualified
electrician.
- The electrical supply must be suitably sized in relation to:
absorbed power specifications indicated on the machine dataplate;
the distance between the machine and the power supply hook-up point, so that
voltage drops under full load do not exceed 4% (10% in the case of start-up) below
the rated voltage specified on the dataplate.
- The user must equip the machine with the following:
a dedicated power plug in compliance with the relevant electrical safety standards;
• a suitable circuit-breaker (residual current set to 30 mA) on the mains connection;
power line fuses in accordance with specifications in the main wiring diagram of this
manual.
• a suitable earthing system installed on the workshop mains line.
- To prevent unauthorised use of the machine, always disconnect the mains plug when
the machine is not used (switched off) for extended periods of time.
- If the machine is connected directly to the power supply by means of the main
electrical panel and without the use of a plug, install a key-operated switch or