COTES LIGHTWEIGHT - USER MANUAL
14/18
Cotes dehumidifier: CL26
Manual number: 140778
Revision: A
COTES.COM
5 / OPERATION
5.1 CONTROL PANEL AND ELECTRICAL INTERFACES
1. Power cable connector
2. Hygrostat connector
3. Mode switch
4. Hour counter
5. Potentiometer (for fan adjustment)
6. Program selector switch
5.2 HOW TO OPERATE THIS DEHUMIDIFIER
Cotes Lightweight dehumidifiers are designed for maximum dehumidification and the standard setting is
continuous operating time. This configuration is intentionally simple, with no dehumidification management
installed.
Starting and stopping the dehumidifier
NOTE
Avoid frequent switching on / off the selector switch as this may damage
the contact element or the connected hygrostat.
The dehumidifier is started and stopped using the selector switch. The selector switch has four positions:
Man = Manual, continuous operation
0 = Switched off
Auto = Automatic, operation with connected hygrostat
Auto + Fan = Automatic, operation with connected hygrostat and fan always on.
Turn the selector swich to the appropriate position to start the dehumidifier in the selected operating mode.
When the selector switch is set to 0, the machine is turned off and all components are without power.
1
2
4
6
5
3