—Donotstoreorusegasolineorotherammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
•Donottrytolightanyappliance.
•Donottouchanyelectricalswitch;donotuse
anyphoneinyourbuilding.
•Immediatelycallyourgassupplierfroma
neighborsphone.Followthegassuppliers
instructions.
•Ifyoucannotreachyourgassupplier,callthe
redepartment.
—Installationandservicemustbeperformedby
aqualiedinstaller,serviceagencyorthegas
supplier.
!
WARNING:Iftheinformationinthese
instructionsisnotfollowedexactly,areor
explosionmayresultcausingpropertydamage,
personal injury or loss of life.
INSTALLER:Leavethismanualwiththeappliance.
CONSUMER:Retainthismanualforfuturereference.
DIRECT VENT
WALL FURNACE
Installation and
Operating Instructions
Cozy Heating Systems, LLC | cozyheaters.com | 855-589-5380 | 3230 Industrial Pkwy | Jeffersonville, IN 47130
CDV15-C
CDV25-C
CDV33-C
The appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home,
where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases, unless a certied kit is used.
- The coating selected to provide longer
life to the heat exchanger may smoke
slightly upon initial ring. Provide
adequate ventilation if this occurs.
- Installation, maintenance, service,
troubleshooting & repairs must be performed
by a qualied service agency. DO NOT
attempt any of these procedures if you are
not qualied as this could expose you to
property damage, personal injury, or loss of
life and will invalidate all warranties.
- This unit is for residential use only and is not
approved for installation in greenhouses,
or environments involving dusty, wet,
corrosive, or explosive conditions. Such
conditions will invalidate the warranty and
may create unsafe conditions.
Natural Gas - CDV155C, CDV255C, CDV335C | Propane Gas - CDV156C, CDV256C, CDV336C

Questions and Answers

  • B
    Brittany HernandezSep 4, 2025
    What causes yellow burner flame in COZY Furnace?
    • M
      Miss Shelia AdamsSep 4, 2025
      A yellow burner flame in your COZY Furnace can be caused by clogged burner ports (remove the main burner and check for obstructions in the throat, ports, and orifices; clean, but do not enlarge ports or orifices) or an obstruction around the vent cap (make sure the area around the vent cap is clear, and be sure the vent system is sealed).
  • A
    Amber CarlsonSep 18, 2025
    How to correct incorrect gas input in COZY CDV155C Wall Furnaces?
    • J
      Jacob TorresSep 18, 2025
      To correct incorrect gas input, first re-check the gas input. If the orifice is clogged, clean it with a smooth wood toothpick, being careful not to enlarge it.
  • C
    Curtis ReyesSep 16, 2025
    What to do if my COZY CDV155C is producing too much heat?
    • L
      Leslie MontgomerySep 16, 2025
      If your furnace is producing too much heat, the thermostat may be set too high. Try lowering the temperature setting. Another possible cause is a combination control valve stuck open, which would require replacing the combination control valve.
  • A
    Alejandro Marks Jr.Sep 14, 2025
    Why is the flame too large in my COZY CDV155C?
    • B
      Brian WarrenSep 15, 2025
      A flame that is too large can be attributed to several factors: a defective operator section of the valve, in which case you should replace the valve; a burner orifice that is too large, so check with your local gas company for the proper orifice size and replace it if necessary; or if the unit is installed above 2,000 ft., refer to the burner orifice section on Page 13.
  • U
    ureedSep 12, 2025
    How to fix delayed ignition in COZY CDV155C Wall Furnaces?
    • A
      Adam JacksonSep 13, 2025
      Delayed ignition can occur for several reasons. The pilot flame might be too small, so adjust it. Burner ports may be clogged at the pilot, requiring cleaning (do not enlarge them). Low gas pressure could be the cause; check the gas supply pressure. If the pilot decreases in size when the main burners come on, the supply piping is too small, and you should consult your local gas company or a competent installer.
  • J
    Jill PenaSep 12, 2025
    What to do if my COZY CDV155C pilot and main burner go out during normal operation?
    • J
      jacqueline78Sep 12, 2025
      If the pilot and main burner go out during normal operation, it could be due to a few reasons. Check for a weak powerpile or thermocouple; test the millivoltage and replace if it's low. The input might be too high, so check the input rate. The cover around the pilot lighter hole might not be airtight; tighten the wing nuts securing the cover and sight glass, and check/replace the gasket if needed. Also, vent tubes might not be properly installed or sealed; follow the instructions to check both exhaust and air intake tubes and the vent cap, ensuring all gaskets are in place and properly sealed, and using only the supplied tubes and vent cap without alterations. Finally, incorrect vent tubes could be the issue; replace them with the correct ones.
  • S
    Shawna CampbellSep 9, 2025
    Why does my COZY CDV155C Wall Furnaces have a yellow burner flame?
    • J
      Julia FordSep 9, 2025
      A yellow burner flame may be caused by clogged burner ports. Remove the main burner and check for obstructions in the throat, ports, and orifices. Clean them, but do not enlarge the ports or orifices. Another cause may be an obstruction around the vent cap. Ensure the area around the vent cap is clear and that the vent system is sealed.
  • T
    Taylor BondSep 7, 2025
    What to do if my COZY Wall Furnaces is not producing enough heat?
    • J
      Jordan ParsonsSep 7, 2025
      If your furnace isn't producing enough heat, there are a few potential causes. First, the furnace might be undersized for the space. Second, the thermostat may be set too low. Try raising the temperature setting. Finally, there could be incorrect supply pressure, which needs to be checked.
  • T
    Teresa BradySep 5, 2025
    What causes too much heat from COZY Furnace?
    • E
      Eric StaffordSep 6, 2025
      If your COZY Furnace is producing too much heat, it might be because the thermostat is set too high (lower the temperature setting) or the combination control valve is stuck open (replace the combination control valve).
  • S
    Shannon OnealAug 21, 2025
    What to do if my COZY Furnace won't ignite?
    • J
      Jenna ColonAug 21, 2025
      If your COZY Furnace fails to ignite, possible causes include the main gas being off (open all manual gas valves), the thermostat not being set high enough (set it to a higher temperature), a clogged burner orifice (clean it, but do not enlarge it), incorrect or defective thermostat wiring (check the wiring, jump across the thermostat terminals at the valve; if the valve opens, re-check the wires and replace the thermostat if needed), or a defective valve (replace the valve).

Summary

Read Carefully Before Installing Unit

Specifications and Dimensions

Introduction to the Wall Furnace

Safety Precautions and Warnings

Venting Installation Guidelines

Required Clearances for Installation

Special Precautions for Safe Operation

Recommended Furnace Location

Installation Procedures

Locate Vent Opening

Instructions for determining and cutting the correct wall opening for the vent system.

Rough-in Gas Supply Installation

Steps for installing the gas supply line, shut-off valve, and pressure tap.

Installing Furnace on Standard Walls

Procedure for mounting the furnace on standard thickness walls using provided components.

Installation for Alternate Wall Dimensions

Gas Connection and Pressure Requirements

Lighting Instructions for the Furnace

Maintenance of the Wall Furnace

Pilot Adjustment Procedure

Procedure for adjusting the pilot flame size for optimal operation and safety.

Burner Orifice Information

Proper Burner Flame Identification

Thermostat Installation Guide

Removing Main Burner for Inspection

Service Records Log

Troubleshooting Common Furnace Issues

DVB-3 Blower Kit Installation (Optional)

BBSK Installation Instructions (Optional)

BBSK-CDV Lighting Instructions (Optional)

Direct Vent Wall Furnace Parts List

Limited Warranty Information

COZY CDV155C Specifications

General IconGeneral
ModelCDV155C
CategoryWall Furnaces
Fuel TypeNatural Gas or Propane
Efficiency80%
VentingDirect Vent
Thermostat ControlYes
Ignition TypeElectronic