DIRECT VENT
COUNTERFLOW
WALL FURNACE
Installation and
Operating Instructions
Cozy Heating Systems, LLC | cozyheaters.com | 888-444-1212 | 250 West Laurel Street | Colton, CA 92324
- The coating selected to provide longer life to the heat exchanger      . Please provide adequate
ventilation if this occurs.
 DO NOT attempt any of


 

 
                       

NATURAL GAS - DVCF403C
-
H, DVCF553C
-
H, DVCF407C-H, DVCF557C-H
PROPANE GAS - DVCF404C-H, DVCF554C-H, DVCF408C-H, DVCF558C-H
DVCF55
DVCF40
WARNING: Operation of this furnace without the properly installed, furnished vent system and vent cap could result in Carbon
Monoxide (CO) poisoning and possible death. For your safety, this furnace and the vent system should be inspected at least
annually by a qualified service technician.
WARNING:
This product can expose you to chemicals including epichlorohydrin
which is known to the State of California to cause cancer and birth defects and/or
other reproductive harm. For information go to 
!
WARNING: 
,
alteration, service or maintenance can cause

for proper installation. For assistance or for

service agency or the gas
supplier.
!
!
WARNING: If the information in these instructions
is not followed exactly, a re or explosion may result
causing property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a qualied
installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Questions and Answers

  • D
    donnafischerSep 23, 2025
    Why is the burner flame yellow on my COZY DVCF40 Wall Furnaces?
    • A
      Alexander PorterSep 23, 2025
      If your COZY Wall Furnaces are producing a yellow burner flame, it could be due to: 1. Clogged burner ports. Remove the main burner and check for obstructions in the throat, ports, and orifices. Clean them, but do not enlarge the ports or orifices. 2. Obstructions around the vent cap. Ensure the area around the vent cap is clear and the vent system is sealed.
  • A
    atorresAug 23, 2025
    Why won't my COZY DVCF40 Wall Furnaces burner turn off?
    • C
      Cody DayAug 23, 2025
      The burner might not turn off due to several reasons. It could be a defective or damaged thermostat wire or the thermostat itself; this can be checked by removing the wire from the valve terminal. If the valve goes off, replace the wire or thermostat. The thermostat location might be incorrect, so follow the installation instructions and check the location. A defective or sticking valve can also cause this issue, requiring valve replacement. Finally, excessive gas pressure could be the cause; contact the utility supplying gas in this case.
  • A
    adamshafferAug 25, 2025
    Why my COZY DVCF40 Wall Furnaces burner won’t turn on?
    • B
      Becky BeasleyAug 26, 2025
      Several issues could prevent the burner from turning on. First, ensure the gas valve is in the “on” position. Check for 24 Volts to the valve from the transformer. Verify the wall thermostat is functioning correctly. Ensure there is 115 V line voltage. The gas valve itself may be defective and need replacement. Lastly, check if the manual reset switch is engaged by depressing the red button on the switch.
  • A
    Ashley NguyenAug 27, 2025
    Why COZY DVCF40 Wall Furnaces standing pilot won’t light or stay lit?
    • P
      Pamela DixonAug 27, 2025
      If the pilot won't light or stay lit, there might be air in the line, so bleed the line. The thermocouple could be defective, so replace it. The pilot flame might be too low, so adjust it. Also, the manual reset switch might not be engaged, so depress the red button on the switch.
  • F
    Frank LoweAug 27, 2025
    What to do if COZY Wall Furnaces I.I.D. pilot won’t light?
    • J
      Jacqueline RodriguezAug 27, 2025
      If the I.I.D. pilot won’t light, check the wire connections for the sparker and provide an adequate ground. If the sparker won’t light the pilot, the pilot flame might be too small, ensure the valve is in the “on” position, and check for any pilot restrictions. Also, verify that the manual reset switch is engaged by depressing the red button on the switch.
  • E
    Erin HarringtonSep 16, 2025
    Why do the pilot and main burner go out during normal operation in my COZY DVCF40?
    • K
      Karina HaleySep 16, 2025
      If the pilot and main burner of your COZY Wall Furnaces go out during normal operation, consider the following: 1. Check the millivoltage of the thermocouple and replace it if it is weak. 2. Check the input rate to ensure it is not too high. 3. Tighten the wing nuts securing the cover and sight glass around the pilot lighter hole to ensure it is airtight. Check and replace the gasket if needed. 4. Inspect both the exhaust and air intake tubes and vent cap to ensure they are properly installed and sealed. Make sure all gaskets are in place and correctly sealed. Use only the supplied tubes and vent cap, and do not alter them.
  • T
    Todd TuckerSep 13, 2025
    Why is my COZY DVCF40 Wall Furnaces not producing enough heat?
    • J
      Joshua OwensSep 13, 2025
      If your COZY Wall Furnaces are not producing enough heat, consider the following: 1. The furnace might be undersized. Have a heat loss calculation performed and compare it to the furnace output. Your gas company can provide this information. If it is undersized, replace it with a unit of the correct size. 2. Ensure the thermostat is set to a sufficiently high temperature. 3. Check the supply pressure to make sure it is correct.
  • M
    michelewallaceSep 15, 2025
    Why is my COZY DVCF40 Wall Furnaces producing too much heat?
    • M
      Mary SmithSep 15, 2025
      If your COZY Wall Furnaces are producing too much heat, consider these solutions: 1. Lower the thermostat setting. 2. The combination control valve might be stuck open, requiring replacement.
  • M
    marissa18Sep 5, 2025
    Why COZY Wall Furnaces has a delayed ignition?
    • B
      Brenda DeleonSep 6, 2025
      A delayed ignition could be due to a few reasons. The pilot flame might be too small, so adjust it. The burner ports might be clogged at the pilot; clean them, being careful not to enlarge them. Low gas pressure could also be the cause, so check the gas supply pressure. Finally, if the pilot decreases in size when the main burners come on, the supply piping is likely too small. Consult your local gas company or a competent installer.
  • O
    ortegaericSep 3, 2025
    What to do if my COZY DVCF40 fail to ignite?
    • J
      Jared CoxSep 3, 2025
      If your COZY Wall Furnaces fail to ignite, here are some potential solutions: 1. Ensure all manual gas valves are open. 2. Set the thermostat to a higher temperature. 3. Clean any clogged burner orifices, being careful not to enlarge them. 4. Check the thermostat wiring. You can jump across the thermostat terminals at the valve; if the valve opens, re-check the wiring or replace the thermostat.

COZY DVCF40 Specifications

General IconGeneral
BTU40, 000
Fuel TypeNatural Gas or Propane
Efficiency80%
VentingDirect Vent
Weight85 lbs
Heating CapacityUp to 1, 000 sq. ft.