DIRECT VENT
COUNTERFLOW
WALL FURNACE
Installation and
Operating Instructions
Cozy Heating Systems, LLC | cozyheaters.com | 888-444-1212 | 250 West Laurel Street | Colton, CA 92324
- The coating selected to provide longer life to the heat exchanger      . Please provide adequate
ventilation if this occurs.
 DO NOT attempt any of


 

 
                       

NATURAL GAS - DVCF403C
-
H, DVCF553C
-
H, DVCF407C-H, DVCF557C-H
PROPANE GAS - DVCF404C-H, DVCF554C-H, DVCF408C-H, DVCF558C-H
DVCF55
DVCF40
WARNING: Operation of this furnace without the properly installed, furnished vent system and vent cap could result in Carbon
Monoxide (CO) poisoning and possible death. For your safety, this furnace and the vent system should be inspected at least
annually by a qualified service technician.
WARNING:
This product can expose you to chemicals including epichlorohydrin
which is known to the State of California to cause cancer and birth defects and/or
other reproductive harm. For information go to 
!
WARNING: 
,
alteration, service or maintenance can cause

for proper installation. For assistance or for

service agency or the gas
supplier.
!
!
WARNING: If the information in these instructions
is not followed exactly, a re or explosion may result
causing property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a qualied
installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Questions and Answers

  • B
    brodriguezSep 8, 2025
    How to fix yellow burner flame in COZY Wall Furnaces?
    • T
      Troy ZhangSep 8, 2025
      A yellow burner flame can be caused by clogged burner ports. Remove the main burner and check for obstructions in the throat, ports, and orifices. Clean them, but do not enlarge the ports or orifices. Another cause could be obstructions around the vent cap. Ensure the area around the vent cap is clear and that the vent system is sealed.
  • J
    John LewisSep 7, 2025
    Why do my COZY DVCF40 Wall Furnaces pilot and main burner go out during normal operation?
    • N
      Natasha FritzSep 7, 2025
      This issue can occur due to several reasons. A weak thermocouple might be the cause; check the millivoltage and replace the thermocouple if it is low. The input might be too high, so check the input rate. Ensure the cover around the pilot lighter hole is airtight by tightening the wing nuts securing the cover and sight glass, and replace the gasket if needed. Also, improperly installed or sealed vent tubes can cause this; follow the instructions to check both exhaust and air intake tubes and the vent cap, ensuring all gaskets are in place and properly sealed, and use only the tubes and vent cap supplied, without altering them.
  • D
    Donna KellyAug 22, 2025
    How to fix COZY DVCF40 Wall Furnaces that fail to ignite?
    • A
      Audrey GarciaAug 22, 2025
      First, ensure all manual gas valves are open. Next, check that the thermostat is set high enough to call for heat by setting the thermostat to a higher temperature. Also, inspect the burner orifice for clogs and clean it, being careful not to enlarge it. Finally, verify the thermostat wiring and replace the thermostat if it's defective.
  • A
    Alan RobinsonSep 4, 2025
    Why COZY Wall Furnaces is not producing enough heat?
    • M
      Marissa WallaceSep 4, 2025
      Several factors can cause insufficient heat. The furnace might be undersized, especially if the room or dwelling has been enlarged. Have the heat loss calculated and compare it to the furnace output. Your gas company can provide this information. If the furnace is undersized, replace it with a correctly sized unit. Also, ensure the thermostat isn't set too low; raise the temperature setting. Finally, incorrect supply pressure can be a factor; check the supply pressure.
  • O
    ortegaericSep 3, 2025
    What to do if my COZY DVCF40 fail to ignite?
    • J
      Jared CoxSep 3, 2025
      If your COZY Wall Furnaces fail to ignite, here are some potential solutions: 1. Ensure all manual gas valves are open. 2. Set the thermostat to a higher temperature. 3. Clean any clogged burner orifices, being careful not to enlarge them. 4. Check the thermostat wiring. You can jump across the thermostat terminals at the valve; if the valve opens, re-check the wiring or replace the thermostat.
  • B
    Brandon LopezSep 1, 2025
    What should I do if the pilot won’t light on my COZY DVCF40 Wall Furnaces (I.I.D. Pilot)?
    • D
      Donna GalvanSep 2, 2025
      If the pilot on your COZY Wall Furnaces (I.I.D. Pilot) won’t light, consider these steps: 1. Check the sparker wire connections and ensure adequate grounding. 2. If the sparker isn’t lighting the pilot, check if the pilot flame is too small, ensure the valve is in the “on” position, and check for any pilot restrictions. 3. Make sure the manual reset switch is engaged by pressing the red button.
  • J
    Joshua AllenAug 31, 2025
    What to do if the pilot won’t light on my COZY Wall Furnaces (standing pilot)?
    • J
      Jonathan CarrollAug 31, 2025
      If your COZY Wall Furnaces pilot won’t light (for standing pilot systems), try the following: 1. Bleed the line to remove any air. 2. Replace the thermocouple if it's defective. 3. Adjust the pilot flame if it’s too low. 4. Ensure the manual reset switch is engaged by depressing the red button.
  • A
    Andrew DelgadoAug 30, 2025
    How to fix a COZY DVCF40 Wall Furnaces burner that won’t turn off?
    • M
      Michael Barton PhDAug 30, 2025
      If your COZY Wall Furnaces burner won’t turn off, it could be due to several reasons: 1. A defective or damaged thermostat wire or the thermostat itself. You can check this by removing the wire from the valve terminal; if the valve turns off, replace the wire or thermostat. 2. The thermostat location might be incorrect; follow the installation instructions to check its placement. 3. The valve might be defective or sticking, requiring replacement. 4. Excessive gas pressure could also be the cause; contact your gas utility provider to check the pressure.
  • Z
    Zachary LeeAug 29, 2025
    Why won't the burner turn on in my COZY DVCF40 Wall Furnaces?
    • M
      Michael MclaughlinAug 29, 2025
      If the burner of your COZY Wall Furnaces won’t turn on, here are several things you can check: 1. Ensure the gas valve is in the “on” position. 2. Verify there is 24V power to the valve from the transformer. 3. Check the wall thermostat. 4. Confirm that 115V line voltage is supplied. 5. If none of these work, the gas valve may be defective and need replacement. 6. Also, make sure the manual reset switch is engaged by depressing the red button on the switch.
  • F
    Frank LoweAug 27, 2025
    What to do if COZY Wall Furnaces I.I.D. pilot won’t light?
    • J
      Jacqueline RodriguezAug 27, 2025
      If the I.I.D. pilot won’t light, check the wire connections for the sparker and provide an adequate ground. If the sparker won’t light the pilot, the pilot flame might be too small, ensure the valve is in the “on” position, and check for any pilot restrictions. Also, verify that the manual reset switch is engaged by depressing the red button on the switch.

COZY DVCF40 Specifications

General IconGeneral
BTU40, 000
Fuel TypeNatural Gas or Propane
Efficiency80%
VentingDirect Vent
Weight85 lbs
Heating CapacityUp to 1, 000 sq. ft.