1018029-E_03/22Page 1
COUNTERFLOW
WALL FURNACE
Installation and
Operating Instructions
Cozy Heating Systems | cozyheaters.com | 888-444-1212 | 250 West Laurel Street | Colton, CA 92324
- The coating selected to provide longer life to the heat exchanger      . Please provide adequate
ventilation if this occurs.
 DO NOT attempt any of


 

 
- THIS UNIT IS NOT TO BE INSTALLED IN MOBILE HOMES.
NATURAL GAS - CF403D
-
H, CF553D
-
H, CF407D-H, CF557D-H
PROPANE GAS - CF404D-H, CF554D-H, CF408D-H, CF558D-H
WARNING: Operation of this furnace without the properly installed, furnished vent system and vent cap could result in Carbon
Monoxide (CO) poisoning and possible death. For your safety, this furnace and the vent system should be inspected at least
annually by a qualified service technician.
CF55
CF40
WARNING:
This product can expose you to chemicals including epichlorohydrin
which is known to the State of California to cause cancer and birth defects and/or
other reproductive harm. For information go to 
!
WARNING: 
,
alteration, service or maintenance can cause

for proper installation. For assistance or for

service agency or the gas
supplier.
!
!
WARNING: If the information in these instructions
is not followed exactly, a re or explosion may result
causing property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a qualied
installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Questions and Answers

  • T
    Travis CurryAug 25, 2025
    Why won't my COZY Wall Furnaces burner turn on?
    • M
      Maria NewmanAug 25, 2025
      If your COZY Wall Furnaces burner won’t turn on, first ensure the gas valve is in the 'on' position. Check for 24 Volts to the valve, and also check the wall thermostat. You can jump the fan switch to check for voltage (the fan will come on). Verify that the auxiliary limit switch and the blocked flue switch are closed by pushing the red button. If none of these steps work, the gas valve may be defective and require replacement.
  • W
    William StewartAug 25, 2025
    What to do if the pilot won’t light or stay lit on my COZY CF403D-H Wall Furnaces?
    • A
      Annette HughesAug 26, 2025
      If your COZY Wall Furnaces pilot won’t light or stay lit (standing pilot), first bleed the line to remove any air. If that doesn't work, the thermocouple may be defective and need replacement. You might also need to adjust the pilot flame if it is too low, or the manual reset switch may not be engaged, so push the button.
  • A
    Ashley RitterAug 27, 2025
    What to do if the pilot light won't ignite on my COZY CF403D-H Wall Furnaces (I.I.D. Pilot)?
    • T
      tatechaseAug 27, 2025
      If the pilot on your COZY Wall Furnaces won’t light (I.I.D. Pilot), check the wire connections and ensure adequate grounding if the sparker isn’t working. If the sparker won’t light the pilot, the pilot flame may be too small, or the valve may not be in the 'on' position; also, check for any pilot restrictions. Ensure the manual reset switch is engaged by depressing the red button on the switch.
  • R
    Rachel MyersAug 27, 2025
    What to do if my COZY Wall Furnaces burner won’t turn off?
    • M
      matthewruizAug 27, 2025
      If your COZY Wall Furnaces burner won’t turn off, it could be due to a defective or sticking automatic valve, which would require replacing the valve. It may also be caused by excessive gas pressure; if the supply gas pressure exceeds 1/2 PSI or 14” W.C., contact the utility supplying the gas to correct this.
  • J
    Joshua RodriguezSep 15, 2025
    How to troubleshoot delayed ignition in COZY CF403D-H Wall Furnaces?
    • T
      Tyler HouseSep 15, 2025
      If your COZY Wall Furnaces shows a delayed ignition, it could be due to several reasons. The pilot flame might be too small; check the pilot orifice and increase pilot gas flow if needed by adjusting the inlet pressure from the gas source. Alternatively, burner ports near the pilot may be clogged, so clean them carefully, making sure not to enlarge them. Low gas pressure could also be the culprit; check the gas supply inlet pressure and the gas outlet (manifold) pressure. The pilot decreasing in size when the main burners come on indicates inadequately sized supply piping or incorrect inlet pressure. Eliminating drafts around the appliance and ensuring proper venting may also resolve the issue.
  • I
    istevensonSep 12, 2025
    What to do if I smell a gas odor from my COZY CF403D-H?
    • Z
      Zachary SanchezSep 12, 2025
      If you smell gas, immediately shut off the gas service and check the piping. Contact your gas company. The odor could also be due to a chimney or flue obstruction, so ensure you clean the flue. Drafts around the COZY Wall Furnaces appliance can also cause a gas odor, so eliminate any drafts in the area.
  • D
    Daniel BrownSep 13, 2025
    Why is the flame on my COZY CF403D-H so noisy?
    • P
      Philip HughesSep 14, 2025
      If the flame on your COZY Wall Furnaces is noisy, it could be due to a noisy pilot; reduce the pilot gas with the adjusting screw on the combination gas control valve. If the noise is a whistle or resonance, there may be a burr in the orifice; remove the burr or replace the orifice, being careful not to enlarge it. Excessive gas input can also cause a noisy flame; refer to the 'Flame Too Large' section for guidance.
  • M
    mezabradleySep 5, 2025
    What to do if the sparker won't light the pilot on my COZY Furnace?
    • V
      vnelsonSep 5, 2025
      If the sparker isn't lighting the pilot, first check the wire connections. If the connections are secure, the pilot flame might be too lean. Ensure the valve is in the 'on' position and check for any pilot restrictions. Also, make sure the manual reset switch is engaged by pushing the button.
  • C
    collinsrobinSep 3, 2025
    Why does my COZY Furnace have a yellow tip flame?
    • K
      Kendra GibsonSep 3, 2025
      A yellow-tipped flame may be due to clogged main burner ports; clean them, but do not enlarge them. Another cause could be a clogged draft hood, so clean the draft hood. Also, check for dust or lint at the air mixer opening.
  • W
    wattsnatashaSep 4, 2025
    How to reduce the flame size on my COZY Furnace?
    • S
      schroedermiguelSep 4, 2025
      A flame that is too large can be caused by a defective operator section of the gas valve, in which case you should replace the complete valve. Alternatively, the burner orifice may be too large; check with your local gas company for the proper orifice size and replace it if necessary. Also, if the furnace is installed above 2,000 feet, consult the orifice chart.

COZY CF403D-H Specifications

General IconGeneral
BrandCOZY
ModelCF403D-H
CategoryWall Furnaces
LanguageEnglish

Related product manuals