1018029-E_03/22Page 11
STANDING PILOT IID PILOT
INSTALLATION
CONTROLS
All controls are pre-assembled at the factory. The normal

      
          



PILOT ADJUSTMENT
         
          
     (see Figure 14). The pilot
          
          
         
(approximately six full turns to bottom of pilot light channel) until
󰀩
The appliance equipped only for altitudes 0 - 2,000 feet. If
installed above 2,000 feet, the BTU input must be reduced 4%



FIG. 12
Installation of
B-W Gas Vent
for one story
buildings or for
first floor of
multi-story
buildings.
Header plate of
vented wall furnace.
(Also acts as firestop)
Use manufacturer’s
method of fastening
pipe to base plate.
Sheet metal screw
base plate to header.
Studs on 16”
centers.
Plate cut away for full
width of stud space
to provide ventilation.
Ceiling plate spacers
to center B-W gas vent
in stud space - nail
securely at both ends.
FIG. 13
Installation of B-W gas vent
for each subsequent ceiling or
floor level of multi-story
buildings.
Firestop spacers supplied by
manufacturer of B-W gas vent.
Plate cut
away to provide
passage of B-W
gas vent.
Nail restop spacer securely.
STANDING PILOT IID PILOT
Honeywell VR8200H Series

Honeywell VR8204H Series

PILOT FLAME ADJUSTMENT

NATURAL GAS
ORDER KIT #49840 2287-1 High Altitude Kit
Model 0’ - 2,000’ - 4,000’ - 6,000’ - 8,000’ -
No. 2,000’ 4,000’ 6,000’ 8,000’ 10,000’
CF403D 32 34 35 36 40
CF407D 32 34 35 36 40
CF553D 29 30 30 31 32
CF557D 29 30 30 31 32
PROPANE GAS
ORDER KIT #49840 2287-1 High Altitude Kit
Model 0’ - 2,000’ - 4,000’ - 6,000’ - 8,000’ -
No. 2,000’ 4,000’ 6,000’ 8,000’ 10,000’
CF404D 49 50 51 52 52
CF408D 49 50 51 52 52
CF554D 2.15mm 45 47 48 49
CF558D 2.15mm 45 47 48 49
ORIFICES
FIG. 14-BFIG. 14-A

