Arial 6.5pt
Arial 6.5pt
Arial Bold 9pt
Arial Bold 6.5pt
Black Black
COLOR:
135
• Conversion to other gas types must be performed by a certified technician only.
This appliance is equipped with a gas pressure regulator. The regulator is factory set at 6” WC for nat, or 10” WC for
propane. For your safety, call an authorized technician for any gas conversion changes. Do not attempt to make conversion
changes yourself.
Any changes made by a non-authorized technician voids warranty. This appliance has been regulated for:
Natural gas 6” WC factory setting
Propane 10” WC factory setting
Note: An authorized technician may convert this unit from one gas type to the other.
Prior to conversion, the unit must be adjusted to the correct gas pressure.
Lighting Instructions
1. Turn all knobs until they are straight up-and-down in the vertical position.
2. Turn on the main valve, and wait 10 seconds to clear the gas for first use.
3. Hold an ignition source (match) at the pilot. When the flame is established, remove the ignition source.
4. Turn the burner knobs to "HIGH". If the burner does not ignite, promptly increase gas flow by continuing to open the pilot valve.
Do this carefully. If the pilot flame appears larger than necessary, turn it down, and reset the burner ignition.
The pilot flame should be just large enough to guarantee reliable burner ignition when the knobs are in the vertical position.
Note: To turn off the pilot burner, the gas supply must first be cut off.