6
CHART ‘A
MODEL
NO
HP VOLT PH Hz
RPM
(Nom)
NEMA
START
CODE
FULL
LOAD
AMPS
SERVICE
FACTOR
SERVICE
FACTOR
AMPS
LOCKED
ROTOR
AMPS
CORD
P/N
CORD
SIZE
CORD
O.D.
WINDING
RESISTANCE
SITHE SCMD
Pump
4SCMD20064 20.0 208 3 60 1750 G 63.0 1.2 74.6 323.0 138318 6/4 - 18/4 1.14 ± .03 0.098
4SCMD25094 25.0
208
3 60 1750 G
77.8 1.2 93.4
359.0 138319 2/4 - 18/4 1.47 ± .03 0.098
230 71.4 1.2 82.3
4SCMD30094 30.0
208
3 60 1750 E
93.4 1.2 116.9
359.0 138319 2/4 - 18/4 1.47 ± .03 0.098
230 82.3 1.2 98.7
4SCMD40034 40.0 230 3 60 1750 E 106.0 1.2 126.4 486.0 138319 2/4 - 18/4 1.47 ± .03 .063
4SCMD40044 40.0 460 3 60 1750 E 53.0 1.2 63.2 243.0 138318 6/4 - 18/4 1.14 ± .03 .248
4SCMD40054 40.0 575 3 60 1750 E 42.4 1.2 50.6 194.4 138317 8/4 - 18/4 1.12 ± .02 .382
SITHE SCMB Pump
4SCMB20064 20.0 208 3 60 1750 G 63.0 1.2 74.6 323.0 138318 6/4 - 18/4 1.14 ± .03 0.88 - 2.14
4SCMB25094 25.0
208
3 60 1750 G
77.8 1.2 93.4
359.0 138319 2/4 - 18/4 1.47 ± .03 0.098
230 71.4 1.2 82.3
4SCMB30094 30.0
208
3 60 1750 E
93.4 1.2 116.9
359.0 138319 2/4 - 18/4 1.47 ± .03 0.098
230 82.3 1.2 98.7
4SCMB40034 40.0 230 3 60 1750 E 106.0 1.2 126.4 486.0 138319 2/4 - 18/4 1.47 ± .03 0.063
4SCMB40044 40.0 460 3 60 1750 E 53.0 1.2 63.2 243.0 138318 6/4 - 18/4 1.14 ± .03 0.248
4SCMB40054 40.0 575 3 60 1750 E 42.4 1.2 50.6 194.4 138318 6/4 - 18/4 1.12 ± .02t 0.382
SITHE SCME Pump
4SCME30094 30.0
208
3 60 1750 E
93.4
1.2
116.9
359.0 138319 2/4 - 18/4 1.47 ± .03 0.098
230 82.3 98.7
4SCME40034 40.0 230 3 60 1750 E 106.0 1.2 126.4 486.0 138319 2/4 - 18/4 1.47 ± .03 .063
4SCME40044 40.0 460 3 60 1750 E 53.0 1.2 63.2 243.0 138318 6/4 - 18/4 1.14 ± .03 .248
4SCME40054 40.0 575 3 60 1750 E 42.4 1.2 50.6 194.4 138317 8/4 - 18/4 1.12 ± .02 .382
4SCME50044 50.0 460 3 60 1750 F 67.1 1.2 79.0 339.0 138318 6/4 - 18/4 1.14 ± .03 .15
4SCME50054 50.0 575 3 60 1750 F 53.7 1.2 63.2 271.2 138318 6/4 - 18/4 1.14 ± .03 .245
4SCME20096 20.0
208
3 60 1150 H
60.3 1.2 71.5
354.0 138318 6/4 - 18/4 1.14 ± .03 .1117
230 57.2 1.2 69.8
SCMEA Pump
4SCMEA20096 20.0
208
3 60 1150 H
60.3 1.2 71.5
354.0 138318 6/4 - 18/4 1.14 ± .03 0.1117
230 57.2 1.2 69.8
4SCMEA25096 25.0
208
3 60 1150 G
75.2 1.2 90.8
354.0 138319 2/4 - 18/4 1.47 ± .03 0.1117
230 70.8 1.2 82.6
4SCMEA25046 25.0 460 3 60 1150 G 35.4 1.2 41.3 177.0 138317 8/4 - 18/4 1.12 ± .02 0.4397
4SCMEA25056 25.0 575
3 60 1150 G 28.3 1.2 33.0 141.6 138317 8/4 - 18/4 1.12 ± .02 0.6857
Moisture and Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5% Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor.
▲ Cord Sufx: XF - 50 Feet, XJ - 75 Feet, or XL - 100 Feet
▲ Cord sold separately.