EasyManua.ls Logo

Creality Falcon2 Pro - Page 40

Creality Falcon2 Pro
209 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
ERROR:05
Description: The machine detected a flame and has stopped working.
Solution:
Press the Reset button to confirm if there is an actual fire hazard. If not, the FIRE light
will turn orange to indicate that there is still a risk of fire.
If the area is safe, press the Start button to resume working. The FIRE light will turn
green, and you can continue.
For more detailed guidance, refer to the "Laser Module Alarm Functions" PDF
included with your device.
You can disable the alarm function by setting $154 to 0, but again, it is recommended
to adjust this setting according to your needs.
ERROR:06
Description: Lens contamination is detected, and the machine has stopped working.
Solution:
Press the Reset button to begin cleaning the lens. The LENS light will turn orange,
indicating the lens needs to be cleaned.
After cleaning, press the Start button to resume working. The LENS light will remain
red when powering on, meaning it needs to be cleaned again.
Press Reset once more after confirming that the lens is clean. The LENS light will turn
green when the issue is resolved.
You can disable the alarm function by setting $155 to 0.
ERROR:07
Description: The laser modules temperature is too high, and the machine has stopped
working.
Solution:
Press Reset and then press the Start button to continue working after the laser
module has cooled.
Make sure to clean the laser module before restarting, and allow it to cool to an
appropriate temperature before resuming work.
You can disable the alarm function by setting $158 to 0.

Related product manuals