39
Troubleshooting
ERROR:01
Description: The angle data is abnormal, and the machine has stopped working.
Solution:
Check whether the workbench is stable or shaking. Any movement could affect the
performance of the machine.
Ensure that all screws are properly tightened to prevent the machine's frame from
moving during operation.
Double-check the frame of the machine to confirm that it is firmly in place.
ERROR:02
Description: No G-code file is found in the root directory of the TF card.
Solution:
Verify that the file in the TF card has the correct suffix (.gcode/.gc/.nc) and that it is
saved in the root directory (not inside any folders).
Make sure that the correct G-code file was generated and properly transferred to the
TF card before beginning the operation.
ERROR:04
Description: No airflow detected, causing the machine to stop working.
Solution:
Check that the air pump is properly connected to the machine.
Confirm that the knob switch on the left side of the machine is adjusted to the
maximum airflow level.
Inspect the silicone air tube above the laser module to ensure there are no blockages
or bends that would impede airflow.
You can also disable the alarm function by setting parameter $153 to 0, but it is
recommended to configure this according to the actual situation.